Article ID: 111212, created on Apr 29, 2011, last review on May 8, 2014

  • Applies to:
  • Virtual Automation 4.5
  • Virtual Automation 4.6


If there are some errors with PVA GUI on Windows 2008 and Windows 2008R2 hosts:
  • Error 403 when try to browse Power Panel on PVC host
  • Inability to see or change settings for application /vz/cp in IIS Manager:


On x64 bit hosts IIS searches for .NET Framework x64 v1.1 configuration, which is not present.
Solution is to copy configuration file from x86 version:
md \windows\\framework64\v1.1.4322\config\
copy \windows\\framework\v1.1.4322\config\machine.config \windows\\framework64\v1.1.4322\config\

edc5403543a5b1f8ebc08b0ce6a492fc 319940068c5fa20655215d590b7be29b d16a8794b3bdb3f66571d469e71906a9 2897d76d56d2010f4e3a28f864d69223