Article ID: 116861, created on Aug 21, 2013, last review on Mar 30, 2016

  • Applies to:
  • Plesk for Windows


MailEnable autoresponder does not send an autoreply.


MTA settings were changed or configured manually.


  1. Check the registry settings for the MTA Mailenable service. In the command line, type:

    reg query "HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Mail Enable\Mail Enable\Agents\MTA" | findstr Pick

    You will receive an output as below:

    Pickup Event Enabled    REG_DWORD    0x1
    Pickup Event Timeout    REG_DWORD    0xea60
    Pickup Event Command Enabled    REG_DWORD    0x0
    Pickup Event Class Name    REG_SZ    pleskmemta.PleskMEMTA
    Pickup Event Class Enabled    REG_DWORD    0x1
    Pickup Event Command    REG_SZ    
  2. If the output is different, please correct the MTA service settings in the registry (Start > Run > regedit.exe) as shown above.

  3. Restart MailEnable services.