Article ID: 117107, created on Sep 4, 2013, last review on Jun 17, 2016

  • Applies to:
  • Virtuozzo 6.0

Symptoms

While restoring container, I have the following error:

~# vzarestore -B -e b11925cd-83df-4848-ac5c-04fd7cb41dd7/20130714233636
Restore container: ct111 from b11925cd-83df-4848-ac5c-04fd7cb41dd7/20130714233636...
* Operation with the  b11925cd-83df-4848-ac5c-04fd7cb41dd7 is started
* Restoring backup b11925cd-83df-4848-ac5c-04fd7cb41dd7/20130714233636 from mypcs.org
* Backup storage: preparing to restore operation
* Backup storage: getting private backup data
* Initializing restore operation
* Operation with the  b11925cd-83df-4848-ac5c-04fd7cb41dd7 is finished with errors: VE exists with uncompatable VE layout. Convert VE 111 to new layout and try again.
Restore failed: VE exists with uncompatable VE layout. Convert VE 111 to new layout and try again
Restore operation failed.

Cause

Container is in old format.

Resolution

To convert container in ploop layout, use the following article #115479.