Article ID: 124170, created on Jan 8, 2015, last review on Jan 8, 2015

  • Applies to:
  • Virtuozzo 6.0
  • Virtuozzo containers for Linux
  • Virtuozzo containers for Windows
  • Virtual Automation 6.0

Symptoms

In Power Panel with default backup type "incremental", upon trying to renew full backup, "Renew backup" execution fails with the error message:

Oct 20, 2014 06:35:14 PM        Starting the process    Completed
Oct 20, 2014 06:35:14 PM        Click here to open/close the operation details.Backup Virtual Environment ct10639       Failed
Oct 20, 2014 06:35:14 PM        Operation with the Container "ct10639" is started        
Oct 20, 2014 06:35:14 PM        Backing up environment ct10639 locally   
Oct 20, 2014 06:35:15 PM        Checking parameters      
Oct 20, 2014 06:35:15 PM        Operation with the Container "ct10639" is finished with errors: A full backup cannot be replaced with an incremental one..  Failed
Oct 20, 2014 06:35:15 PM        Completing the process  Failed

Cause

This issue will be corected in future PVA updates in scope of PVA-34402.

Resolution

The possible workarounds: - use delete button and create a new full backup manually - change default backup type in Virtual Environment Backup Settings in PVA.