Symptoms

Deploying a virtual machine from PVA template fails:

Time    Operation   Status
Jul 02, 2014 01:15:38 AM    Starting the process    Completed
Jul 02, 2014 01:15:38 AM    Click here to open/close the operation details.Create Virtual Machine   Failed
Jul 02, 2014 01:15:38 AM    Operation of "test_resize" is started    
Jul 02, 2014 01:16:31 AM    Copying files from Templates Storage for harddisk.hdd    
Jul 02, 2014 01:20:54 AM    Copying files from Templates Storage for FreeBSD-10.0-RELEASE-amd64-disc1.iso    
Jul 02, 2014 01:20:54 AM    Setting Virtual Machine configuration    
Jul 02, 2014 01:21:23 AM    Operation is finished with errors: Error invoking external utility: Can't resize Virtual Machine device image file. PRL_ERR_IT_FAST_RESIZE_FAILURE. Failed
Jul 02, 2014 01:21:23 AM    Completing the process  Failed

Cause

The issue has been identified as a bug with internal ID #PSBM-27940: a virtual machine is attempted to be resized when copied from PVA template storage, and resize fails because Current size is smaller than Minimum without resizing value.

Resolution

The bug PSBM-27940 has been already fixed in PCS 6.0 update 8. Install pending updates to address the issue.