Article ID: 124615, created on Feb 26, 2015, last review on Feb 26, 2015

  • Applies to:
  • Web Presence Builder 12.0
  • Plesk 11.5 for Linux
  • Plesk 12.0 for Windows
  • Plesk 11.5 for Windows


Attempts to change Administrator's interface language under Home > Profile & Preferences fails with the following message:

SQLSTATE[23000]: Integrity constraint violation: 1062 Duplicate entry '1' for key 'PRIMARY'


The issue is caused by missing user admin in smb_users table of Plesk psa.database.


Steps to resolve the issue:

  1. Make a backup copy of the psa and apsc databases:

    # mysqldump -uadmin -p`cat /etc/psa/.psa.shadow` psa > ~/psa.`date +%F_%H:%M`.sql
    # mysqldump -uadmin -p`cat /etc/psa/.psa.shadow` apsc > ~/apsc.`date +%F_%H:%M`.sql
  2. Check entry for user admin in psa.smb_users table:

    mysql> select * from smb_users where login='admin';
    Empty set (0.00 sec)

    The user with login name admin always has id = 1:

    mysql> select id,login from smb_users where id=1;
    | id |         login          |
    |  1 |    <not_admin_login>   |

    As it can be seen the login name set up incorrectly.

  3. Set up correct name:

    mysql> update smb_users set login='admin' where id=1;

Search Words

SQLSTATE[23000]: Integrity constraint violation: 1062 Duplicate entry '1' for key 'PRIMARY'

Integrity constraint violation


Error change Administrator's interface language

ed7be2b984f9c27de1d2dc349dc19c6d 56797cefb1efc9130f7c48a7d1db0f0c a914db3fdc7a53ddcfd1b2db8f5a1b9c 85a92ca67f2200d36506862eaa6ed6b8 a766cea0c28e23e978fa78ef81918ab8 29d1e90fd304f01e6420fbe60f66f838 9305481d3bd31663b68451e3bfdec5a5 01bc4c8cf5b7f01f815a7ada004154a2 0a53c5a9ca65a74d37ef5c5eaeb55d7f 46a8e394d6fa13134808921036a34da8 bd7fc88cf1b01f097749ae6f87272128 1c99f07514acb28df1f1cbc138d5c135