Article ID: 126018, created on Jun 24, 2015, last review on Mar 24, 2016

  • Applies to:
  • Virtuozzo containers for Windows

Symptoms

  • In clustered environment with Active-Passive nodes, Power Panel service cannot be started on a passive node.

  • Power Panel service does not start automatically after failover.

Cause

PVA Power Panel Director service depends on Parallels Containers Management Service (vzsrv service), which cannot be started on a passive node.

Resolution

In the Windows Cluster Management console, the clustered resource for PVA Power Panel Director can be created as Generic Service.

To add the resource do a "right click" on Application group with containers and chose Add a resource > Generic Service > Select PVA Power Panel Director in the list of available services.

After PVAPP resource is added, it should be configured with proper dependencies:

Right click on the created clustered resource, in Dependencies Tab add the PVA Agent and Parallels Containers Management service as resources that must be brought online before this resource.