Article ID: 126157, created on Jul 12, 2015, last review on Jun 17, 2016

  • Applies to:
  • Virtuozzo 6.0


Starting from Update 7 pstorage top command allows to view the disk info provided by smartctl tool installed along with Virtuozzo storage.

However, after pressing 'd' to switch to the disks table, not all disks in cluster are listed


pstorage top command relies on smartctl output which is different for SATA and SCSI disks or disks attached to a raid controller. pstorage top supports disk monitoring only for SATA disks.

For example, the following smartctl output cannot be parsed by pstorage monitoring script:

# smartctl -A -i /dev/sdb 
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-042stab102.9] (local build)
Copyright (C) 2002-12 by Bruce Allen,
Smartctl open device: /dev/sdb failed: DELL or MegaRaid controller, please try adding '-d megaraid,N'

As result, corresponding disk will be omitted in pstorage top

This behavior recognized as product issue #PSBM-31421


S.M.A.R.T disk monitoring support for other disk types will be implemented in one of the future Virtuozzo Storage Updates.

Search Words

no CS

pstorage top d



RAID controller



c62e8726973f80975db0531f1ed5c6a2 2897d76d56d2010f4e3a28f864d69223 0dd5b9380c7d4884d77587f3eb0fa8ef