Article ID: 126570, created on Aug 16, 2015, last review on Apr 11, 2016

  • Applies to:
  • Odin Business Automation Standard 4.5
  • Virtuozzo


All OS and Application templates are shown as not Synchronized for a Hardware node in OBAS under Top > Service Director > Virtuozzo Manager > Nodes > <name_of_Hardware_node> > OS Templates or Applications. Update Synchronization State button does not solve the issue, templates remain not synchronized.

Task Update synchronization state of templates for <shortname_of_hardware_node> has "Error" status under Action log > Tasks Queue.


RPM database issues on the Hardware Node in question.


Resolve the issue with RPM database on the Hardware Node.

Please be advised that RPM database rebuilding is a purely administrative task and is out of scope of Odin support.

After the RPM database is fixed, press Update Synchronization State button under Top > Service Director > Virtuozzo Manager > Nodes > <name_of_Hardware_node> > Applications or OS Templates.