Symptoms

PVA MN web interface is slow, slave nodes can be shown as offline for a short time.

Top command reveal that mysqld process consumes a lot of CPU time

[root@pva ~]# top
top - 15:05:37 up 1 day, 10 min,  1 user,  load average: 2.45, 2.31, 2.21
Tasks: 103 total,   1 running, 102 sleeping,   0 stopped,   0 zombie
Cpu(s):  8.2%us,  0.9%sy,  0.0%ni, 90.8%id,  0.1%wa,  0.0%hi,  0.0%si,  0.0%st
Mem:   6291456k total,  3890380k used,  2401076k free,        0k buffers
Swap:        0k total,        0k used,        0k free,  3181016k cached

  PID USER      PR  NI  VIRT  RES  SHR S %CPU %MEM    TIME+  COMMAND
  469 mysql     20   0 2580m  48m 5272 S 220.1  0.8   1904:27 mysqld
  587 root      20   0  420m 154m  39m S  1.3  2.5  15:54.40 pvamnd
 1755 root      20   0  309m  73m  62m S  1.3  1.2   6:03.41 pvaccd

Cause

The default value of innodb_buffer_pool_size is 8MB, which may be insufficient for a large database.

Resolution

Increase innodb_buffer_pool_size by adding(adjusting) innodb_buffer_pool_size line to /etc/my.cnf

[root@pva ~]# grep innodb_buffer_pool_size /etc/my.cnf
innodb_buffer_pool_size=24Mb