Article ID: 6617, created on Aug 15, 2009, last review on May 11, 2014

  • Applies to:
  • Sitebuilder 4.5 for Windows

Symptoms

After MSSQL was reinstalled, or you imported database from another server or corrected related accounts, file web.config of Parallels Plesk Sitebuilder contains incorrect information.

For example:

<connectionStrings>
<add name="WSBConnection" connectionString="Connect Timeout=180;Data Source=localhost;User Id=D836976A742949B1B30D3DC3E348DEBD;Pwd=747D358E96B64CEDA4898C077AF0F250WsB-5.0.0-forever!..;Database=sitebuilder5ABE07F3E75B98F48B41A9DBCB1D3791"/>
</connectionStrings>

Resolution

Make sure that UserID, Pwd and Database correspond to those actual in MSSQL.

After all necessary changes, encrypt the configuration file section with the following command:

\WINDOWS\Microsoft.NET\Framework\v2.0.50727\aspnet_regiis  -pef connectionStrings [path to web dir]

4d336e73be6d8fa81454b57cedf8e2bb fad6dc0c8e983c17ae70a51ac7952cd0 2a62cbceb986d1b8f45bcd3ff4cb29a5 45e8c8798afdb3e279a2f84bd498d19e 56797cefb1efc9130f7c48a7d1db0f0c

Email subscription for changes to this article
Save as PDF