PIM shows "500 Application Error" on a brand new Parallels Virtuozzo Containers 4.5 for Windows 2008 server.


The solution is to disable Intel QuickData Technology Device via the Device Manager. Other possible names for the same device are as follows:

    * Intel® 5000 Series Chipset Integrated Device
    * Intel® 5400 Chipset QuickData Technology device
    * Intel® 7300 Chipset QuickData Technology Device
    * Intel® QuickData Technology device