Article ID: 8672, created on Jul 12, 2010, last review on Aug 14, 2014

  • Applies to:
  • Virtuozzo hypervisor


To enable SCSI inside a CentOS 5.x VM, you are advised to perform the following steps:

  1. Download and install the following packages inside the VM:

  2. Add the record below to the "/etc/modprobe.conf" file:

     alias scsi\_hostadapter1 BusLogic
  3. Create a new initrd:

      mkinitrd -f -v /boot/
  4. Change "default=0" in /boot/grub/menu.lst to "default=1":

     title CentOS (
      root (hd0,0)
      kernel / ro root=/dev/VolGroup00/LogVol00
      initrd /
  5. Reboot the VM and check the following:

     lsmod | grep BusLogic
     BusLogic 58369 3
     scsi_mod 196953 5 scsi_dh,sg,BusLogic,libata,sd_mod

    After completing the steps described above, the VM will be able to see the disk and will allow the partitioning of SCSI disks.