Article ID: 1200, created on Mar 16, 2009, last review on May 1, 2014

  • Applies to:
  • Plesk Sitebuilder for Windows

Síntomas

El panel de Parallels Plesk Sitebuilder falla con el siguiente Error de Tiempo de Ejecución:

Server Error in '/' Application.

 --------------------------------------------------------------------------------
 
 Runtime Error
 Description: An application error occurred on the server. The current
    custom error settings for this application prevent the details of
    the application error from being viewed remotely (for security
    reasons). It could, however, be viewed by browsers running on the
    local server machine.
 
 Details: To enable the details of this specific error message to be
    viewable on remote machines, please create a <customErrors> tag
    within a "web.config" configuration file located in the root
    directory of the current web application. This <customErrors> tag
    should then have its "mode" attribute set to "Off".

Causa

Generalmente el problema es que no se ha iniciado el servidor Parallels Plesk Sitebuilder.

Resolución

Abra el símbolo de sistema y ejecute el siguiente comando:

net start "SiteBuilder for Windows Hosting Service"

Asimismo, compruebe que el usuario 'Network/Network Services'  tiene acceso de Lectura y Escritura para la carpeta Temp de Microsoft.Net FrameWork.