Symptômes

[FIX] Le panneau de Parallels Plesj Sitebuilder échoue avec une erreur de fonctionnement

Server Error in '/' Application.

 --------------------------------------------------------------------------------
 
 Runtime Error
 Description: An application error occurred on the server. The current
    custom error settings for this application prevent the details of
    the application error from being viewed remotely (for security
    reasons). It could, however, be viewed by browsers running on the
    local server machine.
 
 Details: To enable the details of this specific error message to be
    viewable on remote machines, please create a <customErrors> tag
    within a "web.config" configuration file located in the root
    directory of the current web application. This <customErrors> tag
    should then have its "mode" attribute set to "Off".

Cause

La plupart du temps, le problème est que le serveur Parallels Plesk Sitebuilder n'est pas démarré.

Résolution

Veuillez ouvrir l'invite de commande et exécuter la commande suivante :

net start "SiteBuilder for Windows Hosting Service"


De plus, veuillez vous assurer que pour le dossier Temp pour Microsoft.Net FrameWork 'Réseau/Services réseau', l'utilisateur a l'accès Lire&Ecrire.

Par exemple, sur le dossier C:\windows\Microsoft.Net\framework\v2.XXXX\Temp (mais le chemin peut être différent).